Hi Ted,
How can I make dt smaller? I have read NEURON NMODL instruction manuel and it said that "neither t nor the time step dt should be changed in NMODL".
What is the default dt value and how I can change it?
Search found 2 matches
- Thu Jun 18, 2020 9:02 pm
- Forum: Adding new mechanisms and functions to NEURON
- Topic: Maximum frequency of current stimulation
- Replies: 3
- Views: 7884
- Thu Jun 18, 2020 4:56 am
- Forum: Adding new mechanisms and functions to NEURON
- Topic: Maximum frequency of current stimulation
- Replies: 3
- Views: 7884
Maximum frequency of current stimulation
Hi, I am trying to simulate current injection stimulation with high frequency( ~MHz). However, when I plot the Curren injection profile, it looks like NEURON cannot follow MHz speed due to the fixed time step(dt) value. What is the maximum frequency that I can apply and is there any way to simulate ...